From: Alteration in ACL loading after total and partial medial meniscectomy
 | Method | AP force (AP moment) | Compression force | APFT | ACL strain (%) |
---|---|---|---|---|---|
Present study | FEA | 108Â N (45Nm) | 520Â N | 4.2Â mm | 5.5 |
Papageorgiou et al. [50] | Experimental | 134 N | 200 N | 4.9 mm | ― |
Lin et al. [51] | Experimental | 134 N | 490 N | 6.0 mm | ― |
Fleming et al. [52] | Experimental | (24Nm) | 240 N | ― | 3.1 |
Asaeda et al. [53] | Experimental | 146 N | 732 N | 4.2 mm | ― |
Rudy et al. [54] | Experimental | 100 N | nil | 5.4 mm | ― |